Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 247
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599688

RESUMEN

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de Registros
3.
Circulation ; 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38660790

RESUMEN

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

5.
J Invasive Cardiol ; 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38547048

RESUMEN

We report the case of an 80-year-old woman with known quadricuspid aortic valve (QAV), severe aortic stenosis, and moderate-to-severe regurgitation who recently underwent a transcatheter aortic valve replacement (TAVR).

6.
JACC Cardiovasc Interv ; 17(6): 715-726, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38456886

RESUMEN

BACKGROUND: Coronary alignment is proposed as an alternative to commissural alignment for reducing coronary overlap during transcatheter aortic valve replacement (TAVR). However, largescale studies are lacking. OBJECTIVES: This study aimed to determine the incidence of coronary overlap with commissural vs coronary alignment using computed tomography (CT) simulation in patients undergoing TAVR evaluation. METHODS: In 1,851 CT scans of native aortic stenosis patients undergoing TAVR evaluation (April 2018 to December 2022),virtual valves simulating commissural and coronary alignment were superimposed on axial aortic root images. Coronary overlap was assessed based on the angular gap between coronary artery origin and the nearest transcatheter heart valve commissure, categorized as severe (≤15°), moderate (15°-30°), mild (30°-45°), and no-overlap (45°-60°). RESULTS: The overall incidence of moderate/severe and severe overlap with either coronary artery remained rare with either coronary or commissural alignment (coronary 0.52% left, 0.52% right; commissural 0.30% left, 3.27% right). Comparing techniques, coronary alignment reduced moderate/severe overlap only for the right coronary artery (0.38% vs 2.97%; P <0.0001). For the left coronary artery, both techniques showed similar moderate/severe overlap, but commissural alignment had significantly higher no-overlap rates (91.1% vs 84.9%; P < 0.0001). Fluoroscopic angle during valve deployment was strongly correlated between commissural and coronary alignment (r = 0.80; P < 0.001). CONCLUSIONS: Using CT simulation, the incidence of coronary overlap with transcatheter heart valve-commissure is rare with commissural alignment. Coronary alignment reduced right coronary overlap, whereas commissural alignment had higher rates of no left coronary overlap. Coronary alignment should be reserved only when commissural alignment results in severe coronary overlap.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Tomografía Computarizada Multidetector
8.
Circ Cardiovasc Interv ; 17(3): e013766, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38502723

RESUMEN

BACKGROUND: Redo-transcatheter aortic valve replacement (TAVR) can pin the index transcatheter heart valve leaflets open leading to sinus sequestration and restricting coronary access. The impact of initial implant depth and commissural alignment on redo-TAVR feasibility is unclear. We sought to determine the feasibility of redo-TAVR and coronary access after SAPIEN 3 (S3) TAVR stratified by implant depth and commissural alignment. METHODS: Consecutive patients with native valve aortic stenosis were evaluated using multidetector computed tomography. S3 TAVR simulations were done at 3 implant depths, sizing per manufacturer recommendation and assuming nominal expansion in all cases. Redo-TAVR was deemed unfeasible based on valve-to-sinotubular junction distance and valve-to-sinus height <2 mm, while the neoskirt plane of the S3 transcatheter heart valve estimated coronary access feasibility. RESULTS: Overall, 1900 patients (mean age, 80.2±8 years; STS-PROM [Society of Thoracic Surgeons Predicted Risk of Operative Mortality], 3.4%) were included. Redo-TAVR feasibility reduced significantly at shallower initial S3 implant depths (2.3% at 80:20 versus 27.5% at 100:0, P<0.001). Larger S3 sizes reduced redo-TAVR feasibility, but only in patients with a 100:0 implant (P<0.001). Commissural alignment would render redo-TAVR feasible in all patients, assuming the utilization of leaflet modification techniques to reduce the neoskirt height. Coronary access following TAV-in-TAV was affected by both index S3 implant depth and size. CONCLUSIONS: This study highlights the critical impact of implant depth, commissural alignment, and transcatheter heart valve size in predicting redo-TAVR feasibility. These findings highlight the necessity for individualized preprocedural planning, considering both immediate results and long-term prospects for reintervention as TAVR is increasingly utilized in younger patients with aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios de Factibilidad , Diseño de Prótesis , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X , Factores de Riesgo
10.
Curr Opin Cardiol ; 39(3): 226-233, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38391273

RESUMEN

PURPOSE OF REVIEW: This review offers insights into percutaneous mitral valve management, emphasizing pivotal trials that contributed to its evolution. RECENT FINDINGS: Mitral regurgitation (MR) is a highly prevalent heart valve disease, with surgical intervention being the gold standard for managing primary MR. However, a notable proportion of patients face ineligibility criteria or are at high surgical risk, particularly in the setting of secondary MR. To fill this gap, transcatheter therapies have emerged as less invasive alternatives. Initially guided by the EVEREST trial criteria, transcatheter leaflet repair techniques have shown impressive technological improvements, addressing nowadays a wide range of anatomical scenarios. Evidence supporting the safety and efficacy of transcatheter leaflet repair is derived from pivotal trials, including EVEREST II, COAPT, MITRA-FR, and CLASP IID, and large multicenter registries including EXPAND, EXPAND G4, and EuroSMR. However, not all patients meet the anatomical and clinical criteria for leaflet repair. For those patients, transcatheter mitral valve replacement may be a minimally invasive option and multiple clinical trials are current underway. SUMMARY: From MitraClip to newer and more innovative technologies, the landscape of percutaneous mitral valve interventions continues to evolve, offering new hopes to patients who may not be ideal candidates for conventional surgery.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Estudios Multicéntricos como Asunto
11.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
12.
Can J Cardiol ; 40(2): 250-262, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38042339

RESUMEN

Mitral regurgitation is a prevalent valvular disease, and its management has gained increasing importance because of the aging population. Although traditional surgery remains the gold standard, the field of transcatheter therapies, including transcatheter edge-to-edge repair and, more recently transcatheter mitral valve replacement are advancing and are being explored as viable alternatives, particularly for patients at high surgical risk. It is essential to emphasize the necessity of a multidisciplinary team approach, involving specialized valve teams, imaging experts, cardiac anaesthesiologists, and other relevant specialists, is crucial in achieving optimal outcomes. Furthermore, proper execution of procedures, postprocedural care, and diligent follow-up for these patients are essential components for successful results. It is essential to underscore that traditional mitral valve surgery continues to play a significant role. Simultaneously, it is important to acknowledge the expanding array of transcatheter interventions available for this specific patient population.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento
13.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
15.
JTCVS Tech ; 22: 1-12, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38152201

RESUMEN

Objectives: Mitral annular calcification remains a formidable lesion in cardiac surgery with significant perioperative morbidity and mortality, particularly when en bloc annular decalcification is implemented. Respect strategies and hybrid approaches have provided safe alternatives. We report the short-term results of our institution's experience with mitral valve replacement in patients with extensive annular calcification. Methods: This is a retrospective review of 72 consecutive patients with extensive annular calcification who underwent open surgical mitral valve replacement from January 1, 2013, to September 31, 2022. Degree of annular calcification was graded as partial, horseshoe, or circumferential. We excluded patients with calcification involving less than one-third of the annulus and patients with rheumatic heart disease. Results: Mean patient age was 71.6 ± 10.9 years, and 50 (69.4%) were female. There were 51 patients (70.8%) with New York Heart Association class 3 or greater and 47 patients (65.3%) with pulmonary hypertension. There were 41 patients (56.9%) with partial, 12 patients (16.7%) with horseshoe, and 19 patients (26.4%) with circumferential calcification. Fifty-six patients (77.8%) underwent conventional valve replacement. Sixteen patients underwent a hybrid procedure using balloon-expandable devices. Concomitant procedures were performed in 61 patients (84.7%). In-hospital mortality and 1-year survival were 3.57% and 82.8% in the standard valve replacement cohort and 25.0% and 54.7% in the hybrid cohort, respectively. Conclusions: Conventional mitral valve replacement using respect strategies is safe and associated with good outcomes in patients with extensive annular calcification. Hybrid approaches using novel devices should remain as a bailout in select patients because of higher perioperative risks and poor short-term outcomes.

16.
Circ Cardiovasc Interv ; 16(11): e012966, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37988437

RESUMEN

Transcatheter aortic valve replacement (TAVR) is increasingly being performed in younger and lower surgical risk patients. Reintervention for failed transcatheter heart valves will likely increase in the future as younger patients are expected to outlive the initial bioprosthesis. While redo-TAVR has emerged as an attractive and less invasive alternative to surgical explantation (TAVR-explant) to treat transcatheter heart valve failure, it may not be feasible in all patients due to the risk of coronary obstruction and impaired coronary access. Conversely, TAVR-explant can be offered to most patients who are surgical candidates, but the reported outcomes have shown high mortality and morbidity. This review provides the latest evidence, current challenges, and future directions on redo-TAVR and TAVR-explant for transcatheter heart valve failure, to guide aortic valve reintervention and facilitate patients' lifetime management of aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
17.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37988439

RESUMEN

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Diseño de Prótesis
18.
Eur J Heart Fail ; 25(12): 2243-2251, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37905381

RESUMEN

AIM: Functional or secondary tricuspid regurgitation (STR) is the most common phenotype of tricuspid regurgitation (TR) with atrial STR (ASTR) and ventricular STR (VSTR) being recently identified as two distinct entities. Data on tricuspid transcatheter edge-to-edge repair (T-TEER) in patients with STR according to phenotype (i.e. ASTR vs. VSTR) are lacking. The aim of this study was to assess characteristics and outcomes of patients with ASTR versus VSTR undergoing T-TEER. METHODS AND RESULTS: Patients with STR undergoing T-TEER were selected from the Transcatheter Tricuspid Valve Therapies (TriValve) registry. ASTR was defined by (i) left ventricular ejection fraction ≥50%, (ii) atrial fibrillation, and (iii) systolic pulmonary artery pressure <50 mmHg. Patients not matching these criteria were classified as VSTR. Patients with primary TR and cardiac implantable electronic device were excluded. Key endpoints included procedural success and survival at follow-up. A total of 298 patients were enrolled in the study: 65 (22%) with ASTR and 233 (78%) with VSTR. Procedural success was similar in the two groups (80% vs. 83% for ASTR vs. VSTR, p = 0.56) and TEER was effective in reducing TR in both groups (from 97% of patients with baseline TR ≥3+ to 23% in ASTR and to 15% in VSTR, all p = 0.001). At 12-month follow-up, survival was significantly higher in the ASTR versus VSTR cohort (91% vs. 72%, log-rank p = 0.02), with VSTR being an independent predictor of mortality at multivariable analysis (hazard ratio 4.75). CONCLUSIONS: In a real-world, multicentre registry, T-TEER was effective in reducing TR grade in both ASTR and VSTR. At 12-month follow-up, ASTR showed better survival than VSTR.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Volumen Sistólico , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/etiología , Función Ventricular Izquierda , Sistema de Registros
19.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37793121

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
20.
Ann Thorac Surg ; 116(5): 908-932, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37804270

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Comorbilidad , Cateterismo Cardíaco/efectos adversos , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...